Fluke 115 Field Service Testing Digital Multimeter
Designed by electricians. Engineered by Fluke.
Compact true-rms meter for field service technicians. The Fluke 115 is the solution for a wide variety of electrical and electronic testing applications.
Also check out the Fluke 114 Electrical Multimeter, the Fluke 116 HVAC Multimeter with Temperature and Microamps, and the Fluke 117, the Electrician’s Multimeter with Non-contact voltage.
Features:
	- Large white LED backlight to work in poorly lit areas
- Resistance and continuity
- Min/Max/Average to record signal fluctuations
- CAT III 600 V safety rated
Safety conformance
All inputs are protected to CE, IEN61010-1 CAT III 600V. CSA and TÜV listed.
Specifications:
	- Maximum voltage between any terminal and earth ground:  600 V
- Surge protection:  6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2
- Display: Digital:  6,000 counts, updates 4 per second
- Bar graph:  33 segments, updates 32 per second
- Operating Temperature:  -10 °C to + 50 °C
- Storage Temperature:  -40 °C to + 60 °C
- Battery type:  9 volt Alkaline, NEDA 1604A/ IEC 6LR61
- Battery Life:  400 hours typical, without backlight
Accuracy Specifications: 
	- DC millivolts: Range:  600.0 mV
 Resolution:  0.1 mV
 Accuracy:  ± ([% of reading] + [counts]): 0.5% + 2
- DC volts: Range/Resolution:  6.000 V / 0.001 V
 Range/Resolution:  60.00 V / 0.01 V
 Range/Resolution:  600.00 V / 0.1 V
 Accuracy:  ± ([% of reading] + [counts]): 0.5% + 2
- AC millivolts1 true-rms: 
 Range:  600.0 mV
 Resolution:  0.1 mV
 Accuracy:  1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz)
- AC volts1 true-rms
 Range/Resolution:  6.000 V / 0.001 V
 Range/Resolution:  60.00 V / 0.01 V
 Range/Resolution:  600.0 V / 0.1 V
 Accuracy:  1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz)
- Continuity
 Range:  600 Ω
 Resolution:  1 Ω
 Accuracy:  Beeper on < 20 Ω, off > 250 Ω; detectsopens or shorts of 500 μs or longer.
- Ohms
 Range/Resolution:  600.0 Ω / 0.1 Ω
 Range/Resolution:  6.000 kΩ / 0.001 kΩ
 Range/Resolution:  60.00 kΩ / 0.01 kΩ
 Range/Resolution:  600.0 kΩ / 0.1 kΩ
 Range/Resolution:  6.000 MΩ / 0.001 MΩ
 Accuracy:  0.9 % + 1
 Range/Resolution:  40.00 MΩ / 0.01 MΩ
 Accuracy:  5 % + 2
- Diode Test
 Range/Resolution:  2.00 V / 0.001 V
 Accuracy:  0.9% + 2
- Capacitance
 Range/Resolution:  1000 nF / 1 nF
 Range/Resolution:  10.00 µF / 0.01 µF
 Range/Resolution:  100.0 µF / 0.1 µF
 Range/Resolution:  9999 µF / 1 µF
 Range/Resolution:  100 µF to 1000 µF
 Accuracy:  1.9% + 2
 Range/Resolution:  > 1000 µF
 Accuracy:  5% + 20%
- Lo-Z Capacitance
 Range:  1 nF to 500 µF
 Accuracy:  10% + 2 typical
 AC amps true-rms (45 Hz to 500Hz)
 Range/Resolution:  6.000 A / 0.001 A
 Range/Resolution:  10.00 A / 0.01 A
- Accuracy:  
 1.5% + 3
 20 A overload for 30-seconds max
- DC amps
 Range/Resolution:  6.000 A / 0.001 A
 Range/Resolution:  10.00 A / 0.01 A
 Accuracy:  1.0% + 3
 20 A overload for 30-seconds max
- Hz (V or A input)2
 Range/Resolution:  99.99 Hz / 0.01 Hz
 Range/Resolution:  999.9 Hz / 0.01 Hz
 Range/Resolution:  9.999 kHz / 0.001 kHz
 Range/Resolution:  50 kHz / 0.01 kHz
 Accuracy:  0.1% + 2
Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F 
2) Frequency is ac coupled, 5Hz to 30 kHz for ac voltage
Mechanical & General Specifications
	- Size:  167 x 84 x 46 mm (6.57" x 3.31" x 1.82")
- Weight:  550 g
- Warranty:  3 years
Model includes the following:
	- Installed 9 V battery
- 4 mm silicone test lead set
- User manual